A SERVICE OF

logo

ZQ110
Rev. 1.00
- 90 -
Mobile Printer Command Manual
Dynamic sentinel character mode
START
characters
(Max 10 byte)
Max DATA 76 characters
(1Track data)
END characters
(Max 10 byte)
0DH 0AH
START
characters
(Max 10 byte)
Max DATA 37 characters
(2Track data)
END characters
(Max 10 byte)
0DH 0AH
START
characters
(Max 10 byte)
Max DATA 104 characters
(3Track data)
END characters
(Max 10 byte)
0DH 0AH
BS M S PL PH fn4 m
[Name]
[Format]
[Range]
[Description]
Transmit Start and End characters setting information
ASCII
BS
M
S
pL
pH
fn4
m
Hex
08
4D
53
pL
pH
34
m
Decimal
08
77
83
pL
pH
52
m
(pL+pHx256) = 2
m = 49, 50, 51
m defines the track to be transmitted.
The transmission format is as follows:
Hexadecimal
Decimal
Amount of Data
Header
37H
55
1 byte
Flag
81H
129
1 byte
Track
31H~33H
49~51
1byte
Start characters
20H ~ 7FH
32~127
Max 10 bytes
Separate
1F
31
1byte
End characters
20H~7FH
32~127
Max 10 bytes
NUL
00H
0
1 byte
- The track on the above table indicates the track information of
transmission data.
- For example, the track value of 31H indicates the information on the Start
and End characters of Track 1.
- If d is set to Null 1-byte in fn3, End characters are not transmitted.