A SERVICE OF

logo

ZQ110
Rev. 1.00
- 25 -
Mobile Printer Command Manual
[Example]
- When MSR set to Track 1/2/3 Read mode
START characters
(Max 10 byte)
Max DATA 76 characters
(1Track data)
END characters
(Max 10 byte)
0DH 0AH
START characters
(Max 10 byte)
Max DATA 37 characters
(2Track data)
END characters
(Max 10 byte)
0DH 0AH
START characters
(Max 10 byte)
Max DATA 104 characters
(3Track data)
END characters
(Max 10 byte)
0DH 0AH
Transmits the setting value format
Hexadecimal
Decimal
Amount of Data
Header
37H
55
1 byte
Flag
80H
128
1 byte
Data
41H ~ 48H
65 ~ 72
1 byte
NUL
00H
0
1 byte
Header
37H
55
1 byte
MSR Setting value
Hex.
Function
41
Track 1/2/3 read mode command (3 Track case)
42
Track 1 read mode AUTO trigger (3 Track case)
43
Track 2 read mode AUTO trigger (3 Track case)
44
Track 3 read mode AUTO trigger (3 Track case)
45
Track 1/2 read mode AUTO trigger (3 Track case)
46
Track 2/3 read mode AUTO trigger (3 Track case)
47
Track 1/2/3 read mode AUTO trigger (3 Track case)
48
MSR not used
Input:
0x1b 0x4d 0x00
0x41 0x42 0x43 0x44 0x45
0x0a
0x1b 0x4d 0x01
0x41 0x42 0x43 0x44 0x45
0xa0
0x1b 0x4d 0x02
0x41 0x42 0x43 0x44 0x45
0a
Output: