A SERVICE OF

logo

ZQ110
Rev. 1.00
- 54 -
Mobile Printer Command Manual
<Function 470> GS ( k pL pH cn fn n (fn=70)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
34
46
n
Decimal
29
40
107
3
0
52
70
n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=52
fn=70
1<=n<=2
n=2
Specify the height of separator between 2D and 1D barcode symbol.
The setting of this command affects <Function 480> and <Function 481>
The setting of this command remains effective until ESC @, printer reset
or power cycling is executed.
<Function 480> GS ( k pL pH cn fn m d1…dk (fn=80)
[Format]
[Range]
[Default]
[Description]
ASCII
GS
(
k
pL
pH
cn
fn
m
d1...dk
Hex
1D
28
6B
pL
pH
34
50
30
d1...dk
Decimal
29
40
107
pL
pH
52
80
48
d1...dk
0<=(pL + pH x 256)<=215 (0<=pL<=215, pH=0)
cn=52
fn=80
m=48
0<=d<=255
k = (pL + pH x 256) 3
Data format : number1...numberN|character1...characterN
Barcode
NumberN
ChracterN
GS1 DataBar
Omnidirectional
0 ≤ numberN ≤ 13
0 ≤ chracterN ≤ 164
GS1 DataBar Truncated
0 ≤ numberN ≤ 13
0 ≤ chracterN ≤ 164
GS1 DataBar Stacked
0 numberN ≤ 13
0 ≤ chracterN ≤ 45
GS1 DataBar Stacked
Omnidirectional
0 numberN ≤ 13
0 ≤ chracterN ≤ 45
UPC-A
0 numberN ≤ 12
0 ≤ chracterN ≤ 164
UPC-E
0 numberN ≤ 12
0 ≤ chracterN ≤ 46
EAN-13
0 numberN ≤ 12
0 ≤ chracterN ≤ 164
EAN-8
0 numberN ≤ 12
0 ≤ chracterN ≤ 106
UCC/EAN-128&CC-A/B
0 numberN ≤ 48
0 ≤ chracterN ≤ 164
UCC/EAN-128&CC-C
0 numberN ≤ 48
0 ≤ chracterN ≤ 164
none
Store GS1 DataBar symbol data in the symbol storage area.