Error Messages
DIAG-REGERR_UNRST
Err#0B16, 0416
[portRegTest, sramRetentionTest]
Port failed to unreset. ASIC failure Replace
mainboard
assembly
DIAG-STATS
Err#2660-2662, 3060 - 3062
[portLoopback Test, crossPortTest]
Port counter value did not match the
number of frames actually transmitted.
Possible counters reporting:
FramesTx - number of frames transmitted
FramesRx - number of frames received
Cl3FrmRx - number of Class 3 frames
received
ASIC, GBIC module
or fiber cable failure
Replace
mainboard
assembly, GBIC
module or fiber
cable
DIAG-TIMEOUT
Err#266F, 306F, 386F
[portLoopbackTest, crossPortTest,
centralMemoryTest]
For portLoopbackTest and crossPortTest:
Port failed to receive frame within timeout
period
For centralMemoryTest:
Port failed to detect an interrupt within the
timeout period.
ASIC, GBIC module
or fiber cable failure
Replace
mainboard
assembly, GBIC
module or fiber
cable
DIAG-XMIT
Err#2271, 2671, 3071, 3871
[portLoopbackTest, crossPortTest,
spinSilk, camTest]
Port failed to transmit frame ASIC failure Replace
mainboard
assembly
Table C-3 Diagnostic Error Messages (continued)
Message Description Probable Cause Action
Table C-4 System Error Messages
Message Description Probable Cause Action
CONFIG CORRUPT The switch configuration
information has become
irrevocably corrupted.
OS error The system automatically
resorts to the default
configuration settings.
CONFIG OVERFLOW The switch configuration
information has grown too large
to be saved or has an invalid size.
OS error Contact customer support.
CONFIG VERSION The switch has encountered an
unrecognized version of the
switch configuration.
OS error The system automatically
resorts to the default
configuration settings.
FABRIC, SEGMENTED,
LOG_WARNING
Fabric segmented. Incompatible fabric
parameters/switches
Conflict zones
Reconfigure fabric or