DS-16B Switch Menus
Switch Management
Error Log Selecting Error Log, then pressing <Enter>, displays:
The error log stores the last 64 error types sensed by the switch. The
front panel display shows:
• Error number (01-64)
• Date and time of the last occurrence each error type was sensed
• Total number of occurrences of each error type
• Error type
• Error level for each error type, with error level 1 being the most
critical; Error level 2 and error level 3, warning, are the other error
levels displayed.
• 0–Panic (when this level is reached, the switch automatically
reboots and the display no longer shows the error)
• 1–Critical
• 2–Error
• 3–Warning
• 4–Info
• 5–Debug
In the sample above, the first line shows that this is the first error (01)
found on Feb 12 08:48:29 and had (23) occurrences. The second line
shows that the error type is SENSOR-FAILED with a severity level of
3 (warning).
The error occurrence count, shown in brackets at the end of the first line, does
not appear until the error occurrence is higher than one.
01 Feb 12 08:48:29 (23)
Err SENSOR-FAILED-3