Error Message Tables
Error Messages
DIAG-LCMTO
Err#1F26, 1026
[centralMemoryTest,
cmemRetentionTest]
Central Memory Timeout: Data transfer
initiated did not complete within the
timeout period.
ASIC failure Replace
mainboard
assembly
DIAG-MEMNULL
Err#0112
[ramTest]
Test failed to malloc. mainboard failure Replace
mainboard
assembly
DIAG-MEMSZ
Err#0111
[ramTest]
Memory size to be tested is less than or
equal to zero
mainboard failure Replace
mainboard
assembly
DIAG-MEMORY
Err#0110
[ramTest]
Data read from RAM location did not
match previously written data into same
location
CPU RAM failure Replace
mainboard
assembly or
DRAM module
DIAG-PORTABSENT
Err#2670, 3070, 3870
[portLoopbackTest, crossPortTest,
spinSilk]
Port is not present ASIC or mainboard
failure
Replace
mainboard
assembly
DIAG-PORTDIED
Err#265F, 305F, 385F
[portLoopbackTest, crossPortTest,
spinSilk]
Port was in loopback mode and then went
inactive
ASIC, GBIC module
or fiber cable failure
Replace
mainboard
assembly, GBIC
module or fiber
cable
DIAG-PORTSTOPPED
Err#3874
[spinSilk]
Port is no longer transmitting, as indicated
by the Number Of Frames Transmitted
counter being stuck at N frames.
ASIC, GBIC module
or fiber cable failure
Replace
mainboard
assembly, GBIC
module or fiber
cable
DIAG-PORTWRONG
Err#3078
[crossPortTest]
Frame erroneously received by port M
instead of the intended port N
ASIC failure Replace
mainboard
assembly
DIAG-POST_SKIPPED
Err# 0004
[switch initialization]
POST is skipped. Its message
recommended that POST be executed.
Informational Only None required
DIAG-REGERR
Err#0B15, 0415
[portRegTest, sramRetentionTest]
Data read from ASIC register or ASIC
SRAM did not match data previously
written into same location
ASIC failure Replace
mainboard
assembly
Table C-3 Diagnostic Error Messages (continued)
Message Description Probable Cause Action