Command
Mode
CONFIGURATION
Command
History
Version Description
9.2(1.0) Introduced on the Z9500 switch.
9.3.0.0 Introduced on the Z9000 switch.
Usage
Information
You can configure HiGig link bundle monitoring so that a system log message or
an SNMP trap is generated when traffic distribution in a bundle is uneven. The
formula that determines uneven traffic distribution is predefined.
hg-link-bundle-monitor rate-interval
Specify the interval (in seconds) for polling traffic distribution in the member links of a HiGig link bundle.
Z9500
Syntax
hg-link-bundle-monitor rate-interval seconds
To restore the default value, use the no version of this command.
Parameters
seconds Polling interval in seconds. The valid values are from 10 to
299.
Command
Mode
CONFIGURATION
Command
History
Version Description
9.2(1.0) Introduced on the Z9500 switch.
9.3.0.0 Introduced on the Z9000 switch.
Defaults The default polling interval for HiGig link bundles is 15 seconds.
Usage
Information
The rate interval used to poll member links is globally configured and applied to all
HiGig link bundles in the system.
hg-link-bundle-monitor trigger-threshold
Specify the bandwidth-percentage threshold used in HiGig link-bundle monitoring to determine uneven
traffic distribution and when an alarm is generated.
Z9500
Syntax
hg-link-bundle-monitor trigger-threshold percentage
To restore the default value, use the no version of this command.
906
Interfaces