HP (Hewlett-Packard) XP24000 Portable Media Storage User Manual


 
Table 33 Cause of Error and the Result of RAID Manager Command (SSB) (continued)
Cause of ErrorRAID Manager CommandSSB2SSB1
Since you specified the XP
Auto LUN target volume as
the XP Snapshot P-VOL, the
command ends abnormally.
For information about using
XP Auto LUN, contact HP
technical support (see
“Contacting HP” (page 116)).
Since you specified the XP
Auto LUN reserved volume
as the XP Snapshot P-VOL,
the command ends
abnormally.
For information about using
XP Auto LUN, contact HP
technical support (see
“Contacting HP” (page 116)).
All commands9759
Since you specified the XP
Business Copy P-VOL as the
XP Snapshot S-VOL, the
command ends abnormally.
All commands975a
Since you specified the XP
Business Copy S-VOL as the
XP Snapshot S-VOL, the
command ends abnormally.
All commands975b
Since you specified the XP
Business Copy reserved
volume as the XP Snapshot
S-VOL, the command ends
abnormally.
All commands975c
Since you specified the XP
Auto LUN source volume as
the XP Snapshot S-VOL, the
command ends abnormally.
For information about using
XP Auto LUN, contact HP
technical support (see
“Contacting HP” (page 116)).
All commands975d
Since you specified the XP
Auto LUN target volume as
the XP Snapshot S-VOL, the
command ends abnormally.
For information about using
XP Auto LUN, contact HP
technical support (see
“Contacting HP” (page 116)).
All commands975e
Since you specified the XP
Auto LUN reserved volume
as the XP Snapshot S-VOL,
the command ends
abnormally.
For information about using
XP Auto LUN, contact HP
technical support (see
“Contacting HP” (page 116)).
All commands975f
paircreate9763
110 Troubleshooting