Sony mz-dh10p MP3 Player User Manual


 
19
MZ-DH10P
5. Press the > key three times to select the item number 9111
and display as follows.
Display of the remote commander
6. And > key once again to select the item number 2251 and
display “251 ChgChk **” on the LCD of remote commander.
7. Press the + , u ENT key on the set or key on the
remote commander confirm that “ADJ OK” is displayed.
8. Press the x key four times and back to the Display Check
mode.
9. Cut the power supply and remove the resistor that connected
to the battery terminals.
3-5. Laser Power Check
Procedure:
1. Enter the test mode (Display Check mode).
2. Press the [VOL+] key to enter the Manual mode.
3. Open the lid and press the . key continuously until the
optical pick-up moves to the most inward track.
4. Press the [VOL--] key once to display as follows.
Display of the remote commander
3-4. Charge Function Check
Note1: When perform this check, don’t apply a voltage to battery terminals.
Note2: Be sure to disconnect the AC adapter when connecting the resistors.
Doing so with the power supply connected causes a trouble.
Procedure:
1. Connect the 10 ohms resistor (more than 3 watts) to battery
terminals.
2. Connect the AC adapter to the battery charging stand in
accessories and set the main unit.
3. Enter the test mode (Display Check mode).
4. Press the [VOL+] key to enter the Manual mode.
5. Press the [VOL+] key twice, press the > key once, press the
[VOL+] key once, press the > key once, press the [VOL+]
key twice to display as follows.
Display of the remote commander
3-6. Setting The Adjustment Values
3-6-1. Hi-MD3 setting
Preparation:
1. Perform calculation every item based on the data given by the
Hi-MD3 adjustment disc by referring to the following table.
(Round off the value in decimal place)
2. Convert the calculated value into hexadecimal number.
Note: The Hi-MD3 adjustment parameters vary depending on the disc,
and therefore use the parameters of the disc used when performing
the adjustment.
Item No. Calculating formula (*3)
0211 Pr_nominal / 0.05
(*1) Por / 0.05
0212 Kr × (100)
0213 Pw_nominal / 0.05
(*2) Ppw / 0.05
0214 Kw × (100)
0215 Prmin / 0.05
0216 Pwmin / 0.05
*1) If the “Pr_nominal” value is indicated, use the “Pr_nominal” value
and not used “Por” value.
*2) If the “Pw_nominal” value is indicated, use the “Pw_nominal” value
and not used “Ppw” value.
*3) Round off after the decimal point.
Table 3-6-1. Hi-MD3 adjustment parameter
Example of Calculation:
Item No. Parameter
Result
Decimal Hexadecimal
0211 Pr_nominal 2.48 mW 50 32h
0212 Kr 0.3 %/°C30 1Eh
0213 Pw_nominal 7.35 mW 147 93h
0214 Kw 0.4 %/°C40 28h
0215 Prmin 1.9 mW 38 26h
0216 Pwmin 5.8 mW 116 74h
Procedure:
1. Enter the test mode (Display Check mode).
2. Press the [VOL+] key to enter the Manual mode.
3. Press the > key once, press the [VOL+] key once, and press
the > key once again to display as follows.
Display of the remote commander
250 ChrgLi
009 DESIGN
111 LrefPw **
210 DiscPr
6. Set the laser power meter so that the laser beam from the optical
pick-up aims at the objective lens of laser power meter at right
angle. (Confirm it with the disc not inserted)
7. Confirm that the value of laser power meter is 0.860 mW ±
19.2%.
8. Press the > key to select the item number 9112.
9. Confirm that the value of laser power meter is 0.763 mW ±
18.2%.
10. Press the > key to select the item number 9113.
11. Confirm that the value of laser power meter is 6.87 mW ±
12%.
12. Press the x key four times and back to the Display Check
mode.
4. Press the > key once to select the item number 0211.
5. Adjust with [VOL+]/[VOL--] keys so that the adjustment value
of LCD becomes calculated value.
6. Press the + , u ENT key on the set or key on the
remote commander to write the adjusted value.
7. Press the > key to next item.
8. Repeat adjustment from step 4 until item number 0216.