Sony mz-dh10p MP3 Player User Manual


 
14
MZ-DH10P
5. MANUAL MODE
This is mode to adjust or check the operation of the set by function.
Operation of The Manual Mode
1. Enter the test mode (Display Check mode).
2. Press the [VOL+] key to activate the Manual mode where the
LCD displays as shown below.
Display of the remote commander
3. During Manual mode, the optical pick-up moves outward or
inward while the > or . key is pressed for several
seconds respectively.
4. Each test item is assigned with a four-digit item number; 1000th
place is a top item, 100th place is a major item, 10th place is a
medium item, and unit place is a minor item.
Flow of manual mode operation:
Number of 1000th place
(000 to 009)
000 Manual
x
key
>
key
>
key
>
key
Top item switching
Major item switching
x
key
[VOL +]
key: 1000th place of item
number increase.
[VOL --]
key: 1000th place of item
number decrease.
[VOL +]
key: 100th place of item
number increase.
[VOL --]
key: 100th place of item
number decrease.
Medium item switching
x
key
[VOL +]
key: 10th place of item
number increase.
[VOL --]
key: 10th place of item
number decrease.
>
key: 1st place of item
number increase.
.
key: 1st place of item
number decrease.
Minor item switching
[VOL +]
key: Increases the adjusted
value.
[VOL --]
key: Decreases the adjusted
value.
Adjusted value variation
Adjusted value write
[
ENT
]
key:
u
Set
[ +],
[
--
]
key:
Remote commander
Adjusted value is written.
5. The display changes a shown below each time the
[DISPLAY] key is pressed.
XXX ***S##
item number
address
Address & Adjusted Value Display
Remote commander LCD display
Remote commander LCD display
adjusted value
XXX ***J##
item number
jitter value
Remote commander LCD display
XXX ******##
item number
item title
adjusted valu
e
adjusted value
Jitter Value & Adjusted Value Display
Block/Bite Error Value & Adjusted Value Display
Bite Error LPF Value & Adjusted Value Display *1)
Focus Drive Value & Adjusted Value Display
Item Title Display
XXX ***B##
item number
block/bite error value
Remote commander LCD display
adjusted value
XXX ***L##
item number
bite error LPF value
Remote commander LCD display
adjusted value
CEMAX Value & Adjusted Value Display *1)
XXX ***C##
item number
CEMAX value
Remote commander LCD display
adjusted value
ADIP Error Value & Adjusted Value Display
XXX ***A##
item number
ADIP error value
Remote commander LCD display
adjusted value
XXX ***F##
item number
focus drive voltage value
Remote commander LCD display
adjusted value
*1) It is skipped excluding the item number 5000 less than 8000.
6. To release the Manual mode, press the x key to return to the
Display Check mode.