r
AR-3000 RS-232C Reference -35
< SU (phrase Set Up for AR-2000)
Function: Phrase setting output
Syntax: stxSU: **** ,“***********”, * , * , * , * , *** , **S* , * , **M**S , * , **M**S, ***, *, *******;
a b c d e f g h I j k l m n o
a Phrase number
b Phrase name (up to 12 characters)
c Phrase type
0 Phrase
1 Pattern Phrase
2 MIDI Phrase
3 Song Phrase
d RDAC-Grade
0 Announce
1 Long 2
2 Long 1
3 Standard
4 High
5 S-High
e RDAC-Mode
0 Linear
1 Mode 1
2 Mode 2
3 Mode 3
4 H-Linear
f Recording Type
0 Mono
1 Stereo
g Playback Volume (10 - 100)
h Delay Time (0S0 - 59S9)
I Repeat Playback
0OFF
1 ON
j Repeat interval (0M0S - 59M59S)
k Control Output
0 OFF
1 ON
l Offset time of control output (0M0S - 59M59S)
m Tempo (5 - 260)
n reserved (Only '0',zero)
o Phrase size (unit: byte)
Note: refer to PQ command