Roland RS 232C MP3 Player User Manual


 
r
AR-3000 RS-232C Reference -29
= AQ (All reQuest)
Function: Reset the Phrase Output Counter
Syntax: stxAQ: * ;
a
a Card in slot
0 Card in slot A
1 Card in slot B
2
Note: This sets the Phrase Output Counter to the lowest-numbered phrase of the phrases
registered in the card. Use this command before you wish to output the settings of all
phrases by using the PQ command, for example when you confirm the initial settings.
= CQ (Card reQuest)
Function: Card setting contents request
Syntax: stxCQ: * ;
a
a Card in slot
0 Card in slot A
1 Card in slot B
Note: refer to CS command
= DQ (Direct play reQuest)
Function: Direct Playback setting contents request
Syntax: stxDQ: * ;
a
a Card in slot
0 Card in slot A
1 Card in slot B
Note: refer to DP command
< IQ (mIdi set up reQuest for AR-2000)
Function: MIDI setting contents request
Syntax: stxIQ: * ;
a
a Card in slot
0 Card in slot A
1 Card in slot B
2
Note: refer to MS command
> JQ (midi set up reQuest for AR-3000)
Function: MIDI setting contents request
Syntax: stxJQ: * ;
a
a Card in slot
0 Card in slot A
1 Card in slot B
Note: refer to ME command