Radio Programming Errors
Programming errors are divided into three categories:
1. Protocol Errors - These are errors produced by the low level communication routines.
2. Radio Errors - These are errors that are returned from the radio ROM or operating software.
3. PC Errors - These are errors that are produced by the PC Programming software.
MESSAGE CODE DESCRIPTION
Successful 0 Command was performed successfully.
Protocol - Canceled by receiver 5 x328 protocol received a cancel. The radio detected a cancel command.
Protocol - Canceled by sender 6 x 328 protocol transmitted cancel. The radio is canceling the read command.
Protocol - Terminate transmission 7 x328 protocol received an end of transmission.
Protocol - Transmit error 8 x328 protocol could not transmit. Reliable communication cannot be established. It could be
the radio or PC hardware problems (programming cable, interface box, or radio hardware).
Protocol - Protocol initialization error 9 x328 protocol not initialized or failed to initialize.
Radio - Programmed successfully 10 Radio responded with a success. Radio acknowledged successful programming.
Radio - Comport configuration failed 11 Radio could not configure its comport (hardware failure).
Radio - Flash erase failed 12 Radio failed to erase the flash memory. The radio flash memory part is unusable or it cannot
detect the 12 volts power. Check the programming box and cables.
Radio - Flash write failed 13 Radio failed in writing to the flash memory. Retry the programming process (hardware
failure).
Radio - Flash code CRC did not match 14 Flash code not programmed correctly. CRC did not match. The operating software will not
execute. Re-program the radio.
Radio - Canceled by receiver 15 The radio operating software received a cancel command.
Radio - Canceled by sender 16
Radio - End of transmission received 17 The radio software received or sent an end of transmission.
Radio - Transmit error 18 Radio could not transmit the required data. Check all hardware connections and try
programming again.
Radio - Invalid command 19 Radio did not understand the received command.
Radio - No application code 20 No application code is loaded, the radio cannot accept personality commands. Re-program the
operating software (flash code) and re-program the personality.
Radio - Application code error 21 The radio application code failed to perform the command.
Radio - EEPROM programming error 22 Could not program the radio EEPROM part.
Radio - Baud rate has changed 23 The radio acknowledged a successful baud communication baud rate change.
PC - Cannot allocate memory 50 The PC programming software could not allocate adequate memory space to perform the
function.
PC - Cannot open data file 51 The specified file (code or personality) could not be opened (file does not exist or has access
protection).
PC - Cannot read data file 52 The specified file (code or personality) could not be read.
PC - Cannot write to file 53 The specified file (code or personality) could not be written.
PC - File not found 54 The specified file (code or personality) is not found in the current directory.
PC - File is larger than radio memory 55 The radio flash part size is unknown or the operating software file size is larger than the radio's
flash memory size.
PC - Incorrect Tracking Data RF band
split
57 Incorrect Tracking Data RF band split.
PC - Incorrect Tracking Data version 58 Incorrect Tracking Data version.
PC - Tracking Data checksum error 59 Tracking Data checksum error.
PC- Time-out, radio not responding 60 Radio is not connected or not turned on or the selected PC comport number is invalid.
PC - Comport configuration error 61 Comport configuration error, cannot set comport.
PC - Abort, message canceled 62 Aborted by operator, message canceled.
PC - Requested personality data does
not exist
63 The personality table does not exist (Tracking or Encryption table).