Ericsson LBI-39175A Portable Radio User Manual


 
LBI-39175
A
21
ROM Fatal Systems Errors
ROM fatal errors may be corrected by cycling the radio power (turn it off then on). When the power cycle does not
correct the problem the radio must be serviced.
ERROR NAME MESSAGE CODE DESCRIPTION
FATAL_SYS_TRAP HARDWARE 0 Fatal system error trap number.
FATAL_NMI_ERROR HARDWARE 1 NMI occurred outside of sleep.
FATAL_RAM_ERROR HARDWARE 2 8K RAM test error.
FATAL_ROM_CHKSUM HARDWARE 3 32K ROM checksum test error.
FATAL_FLSH_CHKSUM HARDWARE 4 Flash checksum test error.
FATAL_ASIC_LOAD HARDWARE 10 ASIC driver failed initialization.
FATAL_ICP_LOAD HARDWARE 11 ICP driver failed initialization.
FATAL_ASP_LOAD HARDWARE 12 ASP driver failed initialization.
FATAL_EE_LOAD HARDWARE 13 EEPROM driver failed initialization.
FATAL_ICP_PORTNIT HARDWARE 14 ICP digital I/O initialization failed.
FATAL_INTOUT_LOAD HARDWARE 15 Standard input/output driver failed initialization.
FATAL_INTIN_LOAD HARDWARE 16 Standard input driver failed initialization.
FATAL_RADIO_LOAD HARDWARE 17 RADIO driver failed initialization.
FATAL_MODEM_LOAD HARDWARE 18 MODEM driver failed initialization.
FATAL_EXTIO_LOAD HARDWARE 19 External I/O driver failed initialization.
FATAL_SCI_LOAD HARDWARE 20 Serial communication interface driver failed initialization.
FATAL _ICP_CHKSUM HARDWARE 21 ICP prom checksum.
FATAL_ADI_NOACK HARDWARE 30 ADI did not respond to command.
FATAL_ADI_QUNDERFLOW HARDWARE 31 ADI Rx circular queue underflowed.
FATAL_LCD_NOACK HARDWARE 40 LCD did not acknowledge message.
FATAL_LCD_HARD_FAIL HARDWARE 41 LCD hardware is invalid.
FATAL_SCI_NOHEAP HARDWARE 50 Serial communication interface out of heap (RAM memory) space.
FATAL_ICP_NOACK HARDWARE 60 ICP did not acknowledge message.
FATAL_EXTIO_ICPFAIL HARDWARE 70 ICP failed in a fork.
FATAL_RADIO_ASPWRT HARDWARE 80 Radio driver could not write to ASP.
FATAL_ROM_NOHEAP HARDWARE 90 Software memory error - ROM task.
FATAL_BL_NOHEAP HARDWARE 91 Software memory error - Boot loader.
FATAL_BL_SCI_ATACH HARDWARE 92 Boot loader could not attach to SCI.
Operational Software Non-Fatal System Errors
ERROR NAME MESSAGE CODE DESCRIPTION
PIFEAT_SNR_ERROR FEAT ERR 550 Feature encryption - Can not read radio ROM serial number.
PIFEAT_READ_ERROR FEAT ERR 551 Personality feature encryption read failure or data not available.
PIFEAT_CRC_ERROR FEAT ERR 552 Decryption failure. Personality feature encryption CRC failure.
RI_DSPDOWN_NOATTEMPT DSP ERR 850 DSP not found
AEGIS_ADIDOWN_
NOTFOUND
DSP ERR 851 DSP file not found.
AEGIS_ADIDOWN_CRCFAIL DSP ERR 852 DSP file not found.
AEGIS_ADIDOWN_ENCERR DSP ERR 853 Radio feature encryption does not match DSP file.
AEGIS_ADIDOWN_PMFAIL DSP ERR 854 DSP file is corrupted or hardware failure. RE-program radio or power cycle the
radio.
AEGIS_ADIDOWN_DMFAIL DSP ERE 855 DSP file is corrupted or hardware failure. Re-program radio or power cycle radio.
AEGIS_ADIDOWN_BIOSERR DSP ERR 856 Hardware failure.
AEGIS_KEYLOAD_
NOBANKS
DSP ERR 860 Personality did not assign banks for the keys.
AEGIS_PVT_NONE FEAT ERR 870 Private is not feature encrypted.