A SERVICE OF

logo

78 Z4Mplus and Z6Mplus User Guide
Configuration
Configuration and Calibration Sequence
Label Positioning Parameters
BACKFEED Press SELECT to make change.
Backfeed Sequence: Press PLUS (+) or MINUS () to
display other choices.
Default: Default (90%)
Selections: Default, after, before, 10%, 20%, 30%, 40%,
50%, 60%, 70%, 80%, off
Press SELECT to accept the change.
This parameter establishes when and how much label
backfeed occurs after a label is removed or cut in the peel-
off or cutter modes. It has no effect in rewind or tear-off
modes. This parameter setting can be superseded by the ~JS
instruction when received as part of a label format (see the
ZPL II Programming Guide Volume I).
The difference between the value entered and 100%
establishes how much backfeed occurs before the next label
is printed. For example, a value of 40 means that 40% of the
backfeed takes place after the label is removed or cut. The
remaining 60% takes place before the next label is printed. A
value of “before” means that all backfeed takes place before
the next label is printed.
LABEL TOP Press SELECT to make change.
Adjusting Label Top Position: Press PLUS (+) to increase
the value, press
MINUS () to decrease the value. The displayed value
represents dots.
Default: +0
Range: –120 to +120 dot rows
Press SELECT to accept the change.
The label top position adjusts the print position vertically on
the label. Positive numbers adjust the label top position
further down the label (away from the printhead); negative
numbers adjust the position up the label (toward the
printhead).
Display Shows Action/Explanation