44
9
SET MODE
New2001
9
DD
Auto power OFF
The receiver can be set to automatically turn OFF after a
specified period with a beep when no key operations are per-
formed.
30 min., 1 hour, 1.5 hours, 2 hours and OFF (default) can be
specified. The specified period is retained even when the re-
ceiver is turned OFF by the auto power OFF function. To can-
cel the function, select “OFF” in this set mode.
DD
Scan pause timer
Selects the scan pause time. When receiving signals, the
scan pauses according to the scan pause time.
• 2–20 : Scan pauses for 2–20 sec. on a received signal,
and selected in 2 sec. steps. (default: 10 sec.)
• HOLD : Scan pauses on a received signal until it disap-
pears. Rotate [DIAL] to resume manually.
DD
Scan resume timer
Selects scan resume time. Scan resumes after the specified
period when the received signal disappears.
• 0 : Scan resumes immediately when the received
signal disappears.
• 1–5 : Scan pause 1–5 sec. after the received signal
disappears. (default: 2 sec.)
• HOLD : Scan pauses on the received signal even if it
disappears. Rotate [DIAL] to resume manually.
DD
Scan stop beep
Turns the scan stop beep function ON and OFF.
When the function is activated (“ON” is selected), a long beep
will sounds each time when signal is received during scan.
No beep is sound when
receiving a signal
A long beep is sound when
receiving a signal
Scan resumes after 2 sec. Scan resumes manually
Scan pauses for 10 sec. Scan pauses until signal
disappears
30 min. timer 2 hrs. timer
IC-R5_1.qxd 02.10.23 11:29 Page 44 (1,1)