Cisco uBR-3x10 RF Switch Hardware Installation and Cabling Guide
OL-1984-06
Chapter 4 Cabling the RF Switch With the Cisco uBR10012 CMTS Cable Interface Line Cards
RF Cable Assemblies for Cisco uBR10-MC5X20S/U/H Line Cards
Figure 4-5 Cable Solution Used with the Cisco uBR10-MC5X20S/U/H Line Card
Universal Cable Holders
Universal cable holders (UCH) are used to attach the cables to the Cisco uBR10-MC5X20S/U/H cable
interface line cards (see Figure 4-5). There are two types of UCH for use with these line cards: UCH1
and UCH2. (For more information, see the Cisco uBR10-MC5X20S/U/H Cable Interface Line Card
document.)
Note Universal cable holders are not included in the RF switch cable kits. The UCH are shipped with the
Cisco uBR10-MC5X20S/U/H cable interface line card cable.
Caution The Cisco uBR10-MC5X20S/U/H cable interface line card must be used with a UCH for all cable
connections to the line card. Failure to use the UCH may cause permanent damage to the line card
connectors, resulting in low or no RF output in the downstream or low or no RF input in the upstream.
Header Blocks
See the “Header Blocks” section on page 4-5. An extraction tool ships with the
Cisco uBR 3x10 RF Switch to remove MCX connectors from the header blocks and UCH, if necessary.
82911
Downstream
0-4
Upstream
10-19
Upstream
0-9
Cisco RF switch 2
Cisco RF switch 1
Cable holder
Header block