PLATFORM_CIGESM-5-UNDR_THERMAL_THRESH1: The Switch Module has recovered from first thermal
threshold.
Explanation This message means that the switch temperature no longer exceeds the first thermal
threshold of 167°F (75°C). Temperature inside the chassis should be monitored.
Response No action is required.
PLATFORM_CIGESM-6-ACQUIRE_IP: Request from Management Module: acquire IP Address from EEPROM.
Explanation This message means that the switch should use the IP address, netmask, and default IP
gateway from EEPROM memory. This information can be configured through the CLI or through the
BladeCenter Management Module WEB page.
Response No action is required.
PLATFORM_CIGESM-6-PICREADFAIL: Read request to PIC microcontroller failed.
Explanation This message means that the PIC microcontroller failed to respond to a Read request. The
PIC microcontroller might be too busy to respond and thus the Read request timed out, or a checksum
error in the communication exists.
Response No action is required.
PLATFORM_CIGESM-6-PICWRITEFAIL: Write request to PIC microcontroller failed.
Explanation This message means that the PIC microcontroller failed to respond to a Write request. The
PIC microcontroller might be too busy to respond and thus the Write request timed out, or a checksum
error in the communication exists.
Response No action is required.
PLATFORM_CIGESM-6-RESETMGMT1: Request from Management Module received: reset ethernet port Gi0/15.
Explanation This message means that the switch had reset port 15, because of a request from the
management module to reset the port.
Response No action is required.
PLATFORM_CIGESM-6-RESETMGMT2: Request from Management Module received: reset ethernet port Gi0/16.
Explanation This message means that the switch had reset port 16, because of a request from the
management module to reset the port.
Response No action is required.