22
MZ-S1
23) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
5B.
24) Press the X key to write the adjusted value.
25) Select manual mode of the test mode, and set item number
777 (see page 16).
26) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
7B.
27) Press the X key to write the adjusted value.
28) Select manual mode of the test mode, and set item number
778 (see page 16).
29) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
7D.
30) Press the X key to write the adjusted value.
31) Select manual mode of the test mode, and set item number
779 (see page 16).
32) Adjust with the
[VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
7F.
33) Press the X key to write the adjusted value.
34) Select manual mode of the test mode, and set item number
781 (see page 16).
35) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
81.
36) Press the X key to write the adjusted value.
777 AD **
Set LCD display
**
: Adjusted value
778 AD **
Set LCD display
**
: Adjusted value
779 AD **
Set LCD display
**
: Adjusted value
781 AD **
Set LCD display
**
: Adjusted value
37) Select manual mode of the test mode, and set item number
865 (see page 16).
38) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
2C.
39) Press the X key to write the adjusted value.
40) Select manual mode of the test mode, and set item number
866 (see page 16).
41) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
B9.
42) Press the X key to write the adjusted value.
43) Select manual mode of the test mode, and set item number
867 (see page 16).
44) Adjust with the
[VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
C9.
45) Press the X key to write the adjusted value.
46) Select manual mode of the test mode, and set item number
868 (see page 16).
47) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
80.
48) Press the X key to write the adjusted value.
865 ###S**
Set LCD display
###
: Address
**
: Adjusted value
866 ###S**
Set LCD display
###
: Address
**
: Adjusted value
867 ###S**
Set LCD display
###
: Address
**
: Adjusted value
868 ###S**
Set LCD display
###
: Address
**
: Adjusted value