A SERVICE OF

logo

DCP42enGB_V1.512/14
18
SwitchingFrequency
4555KHz~
TrackingOverVoltageProtections
O/P010V:SetVoltage+(1.0±0.3V)
O/P1042V:105125%ofsetvoltage
PowerFactor
ControlPowerfactorcorrection:>0.91atoptimalload
CoolingMethod
NaturalConvection
LeakageCurrent
2mA
Protections
Adjustableuppervoltagelimit,Adjustableuppercurrentlimit,
ShortCircuit,Overload,
OverTemperature,TrackingOVP
InputFuse
T3.15AL250V
Safety&EMC
SafetyStandardCE:EN61010
WithstandingVoltageI/PO/P:3.0KVac,I/PF/G:1.5KVac,O/PF/G:0.5KVac
InsulationResistanceI/PO/P,I/PF/G,O/PF/G:100Mohm@500Vdc
EMCCE:EN55011
HarmonicsCurrentEmissionEN6100032
VoltageFluctuations&FlickerEN6100033
EMCImmunityEN6100061
Environmental
WorkingTemperature0to+40°C(32to+104°F)
WorkingHumidity1080%RHNoncondensing
StorageTemperatureandHumidity‐15to+70°C(5to158°F)1085%RHNoncondensing
PollutionDegreeClass2
General
CaseMaterialPolycarbonateFrontPanelandElectroGalvanizedSteelEnclosure
CaseProtectionIP20
ConnectionDia.4.0mmSafetyJackx3(OutputPositive,NegativeandFunctionGround)
Dimensions(WxHxD)200x90x250mm(7.9x3.6x10inch)
Weight2.5kg(5.5lb)