MZ-N510CK
Laser Power Check and Adjustment
Connection
Checking and adjusting method
1. Select the manual mode of test mode (see page 14), and set the
laser power adjusting mode (item number 010).
2. Press the . key continuously until the optical pick-up
moves to the most inward track.
3. Open the cover and set the laser power meter on the objective
lens of the optical pick-up.
4. Press the > key, and set the laser MO read adjustment mode
(item number 011).
5. Check that the laser power meter reading is 0.754 ± 0.13
mW.
6. If the reading value is not satisfied, adjust with the [VOL +]
or [VOL --] key so that the power meter reading becomes the
specification value. Press the X key or press the key on
the remote commander to write the adjusted value.
7. Press the > key, and set the laser CD read adjustment mode
(item number 012).
8. Check that the laser power meter reading is 0.896 ± 0.16 mW.
9. If the reading value is not satisfied, adjust with the [VOL +]
or [VOL --] key so that the power meter reading becomes the
specification value. Press the X key or press the
key on
the remote commander to write the adjusted value.
10. Press the > key, and set the laser MO (X2 speed) write
adjustment mode (item number 013).
11. Check that the laser power meter reading is 4.93 ± 0.59 mW.
12. If the reading value is not satisfied, adjust with the [VOL +]
or [VOL --] key so that the power meter reading becomes the
specification value. Press the X key or press the key on
the remote commander to write the adjusted value.
13. Press the
> key, and set the laser MO (X4 speed) write ad-
justment mode (item number 014).
14. Check that the laser power meter reading is 5.98 ± 0.71mW.
15. If the reading value is not satisfied, adjust with the [VOL +]
or [VOL --] key so that the power meter reading becomes the
specification value. Press the X key or press the key on
the remote commander to write the adjusted value.
16. Press the xCANCEL/CHG key to quit the manual mode, and
activate the test mode (display check mode).
Adjustment required before Overall Adjustment
Note : Modify four adjusted values through the following proce-
dure before performing the CD overall adjustment and MO
overall adjustment.
• Adjusted values modifying procedure
1. Select manual mode of the test mode, and set item number
860 (see page 14).
2. Press the > key to set item number 861.
3. Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
3E.
4. Press the X key or press the key on the remote com-
mander to write the adjusted value.
5. Press the > key to set item number 862.
6. Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
00.
7. Press the X key or press the key on the remote com-
mander to write the adjusted value.
8. Press the > key to set item number 863.
9. Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
37.
10. Press the X key or press the key on the remote com-
mander to write the adjusted value.
11. Press the > key to set item number 864 .
0 10 Laser
Set LCD display
Set LCD display
###S**
0 11
address adjusted valu
e
laser
power mete
r
optical pick-up
objective lens
Set LCD display
###S**
0 12
address adjusted valu
e
-
-
-
-
-
-
-
-
Set LCD display
###S**
0 13
address adjusted valu
e
Set LCD display
###S**
0 14
address adjusted valu
e
861 ###S**
Set LCD display
**
: Adjusted value
862 ###S**
Set LCD display
**
: Adjusted value
863 ###S**
Set LCD display
**
: Adjusted value
864 ###S**
Set LCD display
**
: Adjusted value
-
-
-
-
-
-