15
MZ-N510CK
5. The display changes a shown below each time the [END
SEARCH] key is pressed.
However in the power mode (item number 700’s), only the
item is displayed.
6. Quit the manual mode, and press the xCANCEL/CHG key to
return to the test mode (display check mode).
Overall Adjustment Mode
Mode to adjust the servo automatically in all items.
Normally, automatic adjustment is executed in this mode at the
repair.
For further information, refer to “SECTION 5 ELECTRICAL
ADJUSTMENTS” (see page 19).
item number
address adjusted value
• Address & Adjusted Value Display
Set LCD display
• Jitter Value & Adjusted Value Display
Set LCD display
• Block Error Value & Adjusted Value Display
Set LCD display
• ADIP Error Value & Adjusted Value Display
Set LCD display
• Focus Drive Value & Adjusted Value Display
Set LCD display
• Item Title Display
Set LCD display
C68S1B
0 11
0FEJ1B
0 11
063B1B
0 11
081A1B
0 11
000F1B
0 11
LrefPw
0 11
item number
jitter value adjusted value
item number
block error value
adjusted value
item number
ADIP error value
adjusted value
item number
focus drive value
adjusted value
item number
item title
Self-Diagnosis Result Display Mode
This set uses the self-diagnostic function system in which if an
error occurred during the recording or playing, the mechanism
control block and the power supply control block in the
microcomputer detect it and record its cause as history in the
nonvolatile memory.
By checking this history in the test mode, you can analyze a fault
and determine its location.
Total recording time is recorded as a guideline of how long the
optical pick-up has been used, and by comparing it with the total
recording time at the time when an error occurred in the self-
diagnosis result display mode, you can determine when the error
occurred.
Clear both self-diagnosis history data and total recording time, if
the optical pick-up was replaced.
• Self-Diagnosis Result Display Mode Setting Method
1. Set the test mode (see page 13).
2. In the display check mode, press the [GROUP] key activates
the self-diagnosis result display mode where the LCD display
as shown below.
3. Then, each time the
> key is pressed, LCD display descends
by one as shown below. Also, the LCD display ascends by one
when the . key is pressed.
If the
[GROUP] key is pressed with this display, the LCD switches
to the simple display mode.
4. Quit the self-diagnosis result display mode, and press
the xCANCEL/CHG key to return to the test mode (display
check mode).
0 XX 1 ****
0 XX N ****
0 XX N1****
0 XX N2****
0 XX R_****
1
1
XX
: Error code
****
: Total recording time
0 XX 1 0000
history code
error display code
Total recording time
when error occurred
Set LCD display