B. ELECTRICAL INSTALLATION
1. The fryer is equipped with a three-prong grounding plug (NEMA 15-5P) for your protection
against shock hazard. The fryer must be plugged directly into a properly grounded three-prong
receptacle (NEMA 15-5R).
2. The installation of this fryer must conform to local codes. In the absence of local codes, the
installation of this fryer must conform with the National Electrical Code (ANSI Z223.1).
In Canada, CSA C22.2 is applicable.
3. DO NOT obstruct the flow of the two exhaust flues (item 14) at the top rear of the fryer. It is
especially critical that gas supply piping and electrical supply cord and/or receptacle be routed
away from the path of the hot combustion fumes.
4. Because the fryer draws less than 8 amps, two fryers may be plugged into the same 15 amp
circuit if required.
CAUTION - ELECTRICAL SHOCK HAZARD
DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG.
Ungrounded electrical equipment cause personal injury
and property damage.
NEMA 5-15R
RECEPTACLE
NEMA 5-15P
PLUG
GROUND
PRONG