A SERVICE OF

logo

TROUBLESHOOTING OPERATIONAL PROBLEMS
NOTE: The fryer has two independent burner systems, whose only common components are in
the control system (CONTROLLER, TEMPERATURE PROBE and HI-LIMIT THERMOSTAT).
Troubleshooting efforts should isolate a problem to either: an individual burner system; or, to the
control system.
PROBLEM POSSIBLE CAUSE SOLUTION
READOUT not lit POWER SWITCH not Press POWER SWITCH
(Fryer not operating) in FRYER position to FRYER position
Circuit breaker OFF or tripped Reset circuit breaker
Service wiring problem Correct service wiring
Controller connection faulty Check / replace connector
(Fryer operating norm.) CONTROLLER defective Replace CONTROLLER
HEAT LIGHT not lit Programmed temperature Raise programmed temperature
(READOUT lit and too low / select another MENU KEY
Cooking oil cold) CONTROLLER defective Replace CONTROLLER
HI-LIMIT THERMOSTAT Allow oil to cool
TRIPPED Reset HI-LIMIT
COOKING OIL COLD BURNER SYSTEM problem Correct burner problem
(HEAT light lit) Wiring problem / loose connection Correct wiring problem
Defective PROBE Replace PROBE
CONTROLLER defective Replace CONTROLLER
CRADLE LIFT won’t Improper key strokes Press”BASKET” then “DOWN
lower ARROW”
BASKET "DOWN" RELAY defective Replace RELAY
LIFT MOTOR defective Replace LIFT MOTOR
Wiring problem / loose connection Correct wiring problem
CONTROLLER defective Replace CONTROLLER
CRADLE LIFT won’t READOUT not “00:00” or “PAUSE” Press “PAUSE” + “UP ARROW”
raise BASKET "UP" RELAY defective Replace RELAY
LIFT MOTOR defective Replace LIFT MOTOR
Wiring problem / loose connection Correct wiring problem
CONTROLLER defective Replace CONTROLLER
BUZZER does not Buzzer programmed OFF Contact factory for instructions
sound BUZZER defective Replace BUZZER
Wiring problem / loose connection Correct wiring problem
CONTROLLER defective Replace CONTROLLER
BUZZER not loud enough BUZZER SHUTTER closed Open SHUTTER
MENU KEY does not MENU KEY not programmed Program MENU KEY
operate CONTROLLER defective Replace CONTROLLER
FUNCTION KEY does Improper KEY ENTRY Consult OWNERS MANUAL
not operate for proper usage
CONTROLLER defective Replace CONTROLLER
9