Factory Reset
Factory Reset clears all user settings from KeypadLinc including INSTEON Scenes, On-Levels, Ramp
Rates, X10 addresses, etc.
1) Pull Set button out (creating an Air Gap)
2) Wait 10 Seconds
3) Push Set Button in and Hold it in
KeypadLinc will (Beep)
4) Release the Set button
Device’s embedded software will re-write all settings to factory defaults
A couple of seconds will pass
KeypadLinc will (Beep)-(Beep)
LEDs will return to normal brightness
KeypadLinc returns to Ready Mode
The connected load will turn on
Specifications
WILL POPULATE WITH NEW SPECIFICATION LIST
TROUBLESHOOTING
Problem
Possible Cause
Solution
The
indicator lights under
the KeypadLinc buttons
are not illuminated.
The KeypadLinc is not
controlling the load.
KeypadLinc may not be
getting power.
Make sure the circuit breaker is turned on.
Make sure the air gap (Set button) is not pulled out.
Check the junction box wires to ensure all connections
are tight and no bare wires are exposed.
Make sure the Line and Load wire are not mis-wired
inside the junction box.
Check the connected load to ensure all connections are
tight and no bare wires are exposed.
KeypadLinc won’t Link or
work with a Controller or
Responder.
The Controller or Responder
might have been reset
without Unlinking KeypadLinc
from it.
Re-Link KeypadLinc to the Controller or Responder.
The Controller or Responder
and KeypadLinc may be on
opposite power line phases.
Make sure two dual-band INSTEON devices are
properly installed to bridge the two power line phases.
The INSTEON signal may be
too weak.
Add additional INSTEON devices or move around
existing INSTEON devices. All INSTEON devices act as
INSTEON network repeaters to improve communication
signals.