Power Specifications
24-port 4-Gbps switching
module, DS-X9124
3.x 147 628 2.04 1.53 1.02 0.77
2.x and
1.x
—— ————
12-port 4-Gbps switching
module, DS-X9112
3.x 132 564 1.83 1.38 0.92 0.69
2.x and
1.x
—— ————
4-Port 10-Gbps switching
module, DS-X9704
3.x 172 734 2.39 1.79 1.19 0.90
2.x and
1.x
—— ————
32-port 1-Gbps/2-Gbps Fibre
Channel module, DS-X9032
3.x 191 816 2.65 1.99 1.33 0.99
2.x and
1.x
200 855 2.78 2.08 1.39 1.04
16-port 1-Gbps/2-Gbps Fibre
Channel module, DS-X9016
3.x 210 897 2.92 2.19 1.46 1.09
2.x and
1.x
200 940 3.05 2.29 1.53 1.15
MSM-18/4 module
DS-X9304-18K9
3.2(1) 200 855 2.78 2.08 1.39 1.04
MSFM-18/4 module
DS-X9304-18FK9
3.2(1) 200 855 2.78 2.08 1.39 1.04
MPS-14/2 DS-X9302-14K9 3.x 200 854 2.78 2.08 1.39 1.04
2.x and
1.x
227 970 3.15 2.37 1.57 1.19
8-port IPS module
DS-X9308-SMIP
3.x 200 854 2.78 2.08 1.39 1.04
2.x and
1.x
220 940 3.05 2.29 1.53 1.15
4-port IPS module
DS-X9304-SMIP
3.x 160 683 2.22 1.67 1.11 0.83
2.x and
1.x
185 789 2.57 1.93 1.28 0.96
32-port SSM,
DS-X9032-SSM
3.x 281 1200 3.90 2.93 1.95 1.46
2.x and
1.x
295 1260 4.10 3.07 2.05 1.54
32-port ASM
DS-X9032-SMV
3.x 281 1200 3.90 2.93 1.95 1.46
2.x and
1.x
295 1260 4.10 3.07 2.05 1.54
CSM,
DS-X9560-SMC
3.x 200 854 2.78 2.08 1.39 1.04
2.x and
1.x
210 907 2.95 2.22 1.48 1.11
Table B-7 Power Requirements and Heat Dissipation for the 845-W Power Supply (continued)
Module Type /
Product Number
NX-OS
Release
SAN-OS
Release
Power
Required
(watts)
Heat
Dissipation
(BTU/hr)
Input Current
90 VAC
(amps)
120 VAC
(amps)
180 VAC
(amps)
240 VAC
(amps)