9.1.8 Adjustment of Temp reading,C17 (0°C TMP)
Value to adjust the temperature.
To add, use underlining character ( _ ) ahead of the digit ( _1
TMP).
To subtract, use minus character ( - ) ahead of the digit (-1 TMP).
9.1.9 Unit for Air Pressure, C18 (Unit hPA)
Future function. Unit for air pressure. Hecto Pascal (hPa) or Inch
HG (INH).
9.1.10 Unit for Wind Speed, C19 (Unit m/s)
Unit for wind speed. Metre/second (m/s), knots (KTS) or Beaufort
(BF).
Note, this is a local setting and has to be done on both Sea Data
and the Wind instrument
9.1.11 Adjustment of Wind Angle, C20 (000° ADJ)
Mast top unit misalignment adjust value or the so called ”A-fault”,
makes it possible to choose any horizontal mounting angle.
Example 1: If the wind angle is +4° (from Starboard) when you
sail/drive the boat straight into the wind. Set the calibration
channel C54 to 356°.
Example 2: If the wind angle is -4° (from port) when you sail/drive
the boat straight into the wind. Set the calibration channel C54 to
004°.
9.1.12 Damping of Wind Readings, C21 (SEA LOW)
Damping of wind information. Controls the response time of wind
changes. To change damping, press SET. To select damping
level, press PLUS and select from: LOW) 1 sec, (MED) 5 sec and
(MAX) 22 sec. To store the selected value, press SET.
Factory value is (LOW), for use in calm sea. But if the sea is
rough, you may want to ”stabilise” the readout on the display, then
select MID or (MAX). Damping is set separately for each
instrument.
9.1.13 Key beep setting, C22 (OFF KEY)
(On) = Sound when push buttons are pressed. (OFF) = no sound.