La Crosse Technology WS-1613-IT Portable Radio User Manual


 
24
2. Press and hold the SET key for about 2 seconds. The hour digit of the alarm
time will start flashing. Press the + or MIN/MAX key to set the hour of the alarm
time.
3. Press the SET key to confirm and advance to the minute setting. The minute
digit will be flashing.
4. Press the + or MIN/MAX key to set the minute of the alarm time. Press the
ALARM key to confirm. Wait for about 30 seconds and the display will return to
normal display mode automatically.
5. In the normal display mode, press the ALARM once key to go to the time alarm
setting mode again. Then press shortly the SET key to switch on or off the time
alarm. (The showing of the icon (((y))) means that the time alarm is switched on.)
6. Press the HISTORY key or wait for about 30 seconds and the display will return
to normal display mode automatically.
Note:
The alarm ringing duration is 2 minutes. To stop the alarm, press any key during the
alarm ringing.
WEATHER ALARM OPERATIONS
The Weather alarms can be set when certain weather conditions are met according to
your requirements. For example, you can set the thresholds for the outdoor
temperature to +104°F (+40°C) (high) and 14°F (-10°C) (low), while only enabling the
high alarm and disabling the low alarm (i.e. temperatures <14°F (-10°C) won’t trigger
alarm, but temperatures >+104°F (+40°C) will).
25
The Weather Center can be set to alert when a specific weather condition is reached.
The following Weather Alarm settings can be adjusted in the ALARM setting
mode.
High outdoor temperature alarm
Low outdoor temperature alarm
High outdoor humidity alarm
Low outdoor humidity alarm
High wind speed alarm
High wind
speed Alarm-
On icon
Outdoor humidity
Alarm-On icon
Outdoor temp
Alarm-On icon
26
Default alarm values:
Low
32°F (0°C)
Temperature
High
104°F (40°C)
Low 45% Relative
Humidity
High 70%
Wind speed High 62.0mph (100km/h)
HIGH AND LOW OUTDOOR TEMPERATURE ALARM SETTING
Note:
The High and Low outdoor temperature alarm can be set On/Off independently,
according to your needs.
Set the Outdoor temperature alarm value (High or Low alarm value) :
1. In the normal display mode, press the ALARM key twice. The High Outdoor
Temperature alarm display will be shown.
2. Press and hold the SET key for about 2 seconds. The temperature digit will start
flashing. Press the + or MIN/MAX key to set the high outdoor temp alarm value.
(Keep holding the key will allow the value to increase faster.)
High alarm icon
Alarm-On icon
27
3. Press the ALARM key to confirm the setting. The digit will stop flashing. Press
the SET key to switch on or off the alarm. (The showing of the icon (((y))) means
that the alarm is switched on.)
4. Press the ALARM key once. The Low Outdoor Temperature alarm display will
be shown.
5. Press and hold the SET key for about 2 seconds. The temperature digit will start
flashing. Press the + or MIN/MAX key to set the low outdoor temp alarm value.
(Keep holding the key will allow the value to increase faster.)
6. Press the ALARM key to confirm the setting. The digit will stop flashing. Press
the SET key to switch on or off the alarm. (The showing of the icon (((y))) means
that the alarm is switched on.)
7. Press the HISTORY key or wait for about 30 seconds and the display will return
to normal display mode automatically.
In case the temperature value meets the condition for high alarm or low alarm, the
value will be blinking, along with the corresponding icon ("HI AL"/ "LO AL").
And the buzzer will ring for 2 minutes. User then may press any key to stop the ring.
User may quit the alarm setting and return to the normal display mode by pressing the
HISTORY key.
HIGH AND LOW OUTDOOR HUMIDITY ALARM SETTING
Note:
The High and Low outdoor humidity alarm can be set On/Off independently according
to your needs.
28
Set the Outdoor temperature alarm value (High or Low alarm value):
1. In the normal display mode, press the ALARM key 4 times. The High Outdoor
Humidity alarm display will be shown.
2. Press and hold the SET key for about 2 seconds. The humidity digit will start
flashing. Press the + or MIN/MAX key to set the high outdoor humidity alarm
value.
3. Press the ALARM key to confirm the setting. The digit will stop flashing. Press
the SET key to switch on or off the alarm. (The showing of the icon (((y))) means
that the alarm is switched on.)
4. Press the ALARM key once. The Low Outdoor humidity alarm display will be
shown.
5. Press and hold the SET key for about 2 seconds. The humidity digit will start
flashing. Press the + or MIN/MAX key to set the low outdoor humidity alarm
value.
6. Press the ALARM key to confirm the setting. The digit will stop flashing. Press
the SET key to switch on or off the alarm. (The showing of the icon (((y))) means
that the alarm is switched on.)
7. Press the HISTORY key or wait for about 30 seconds and the display will return
to normal display mode automatically.
In case the humidity value meets the condition for high alarm or low alarm, the value
will be blinking, along with the corresponding icon ("HI AL"/ "LO AL"). And the buzzer
will ring for 2 minutes. User may press any key to stop the sound.
29
WIND SPEED ALARM SETTING
The High wind speed alarm can be set by following the steps below.
1. In the normal display mode, press the ALARM key six times. The High wind
speed alarm display will be shown.
2. Press and hold the SET key for about 2 seconds. The wind speed digit will start
flashing. Press the + or MIN/MAX key to set the high wind speed alarm value.
3. Press the ALARM key to confirm the setting. The digit will stop flashing. Press
the SET key to switch on or off the alarm. (The showing of the icon (((y))) means
that the alarm is switched on.)
4. Press the ALARM key once to return to the normal display mode.
In case the wind speed exceeds the condition for high wind speed alarm, the value
will be flashing, along with the corresponding high alarm icon ("HI AL"). And the
buzzer will ring for 2 minutes. User may press any key to stop the sound.
HYSTERESIS
To compensate for fluctuation of the measured data, which may cause the weather
alarm to sound constantly if the measured reading is close to your set level, a
hysteresis function has been implemented for each weather alarm. For example, if the
high temperature alarm is set to +77°F (25°C) and the current value moves to +77°F
(25°C), the alarm will be activated (if it has been enabled). Now when the temperature