A-18 Appendix A
Error Code and Qualifier Reference
Library Error Codes
60 3CH Internal bus command did not
complete successfully.
• Run Recalibrate Library test,
followed by
Check Inventory
test.
• Power cycle.
83 53H A diagnostic test failed to
complete.
• Run
Recalibrate Library test,
followed by
Check Inventory
test.
• Run diagnostic test again.
86 56H A command sent to the transport
timed out.
• Verify that the transport
LEDs are on and green.
• Clear any obstructions from
the transport path.
87 57H A command to the transport was
corrupted.
• Power cycle.
88 58H Attempted to overlap commands
to the transport controller.
• Run
Recalibrate Library test.
• Clear the transport path.
• Power cycle.
89 59H The transport lost power. • Run
Recalibrate Library test.
90 5AH Vertical system failed wakeup
from powersave mode.
• Run
Recalibrate Library test.
• Check internal cables.
91 5BH Status report from transport was
corrupted.
• Power cycle.
92 5CH Transport timed out while
executing a command.
• Verify that the transport
LEDs are on and green.
• Clear any obstructions from
the transport path.
Table A-2 Error Code Qualifiers
Decimal
Error
Hex
Error
Description Recovery Method