![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/b/c2/bc2d2126-64d3-49bf-b5ef-f2663d4b760b/bc2d2126-64d3-49bf-b5ef-f2663d4b760b-bg4d.png)
975-0082-01-01 67
Operation of the Xanbus AGS
Modes of Operation
The AGS, like all other Xanbus-enabled devices, supports two modes,
Operating and Standby. The AGS mode of operation must be set to Standby
before selecting a Generator Type. Selecting Standby stops the generator (if
it is running).
While in Standby, the AGS “listens” to and reports its status to the network.
However, it will not start the generator manually or automatically while in
Standby.
If the AGS is powered off while in Standby, it will be in Standby when it is
powered on again.
The AGS can also be put in Standby using the system mode option under
system settings. However, note that selecting Standby from system settings
affects the behavior of the entire Freedom SW system. System mode
Standby puts every Xanbus-enabled device in Freedom SW Power System
into Standby.
Putting the AGS in Standby Mode
Use the Xanbus System Control Panel (SCP) to put the AGS into Standby
mode.
IMPORTANT:
If AGS Fault 201 “Unable to stop gen.” is active, the AGS
cannot be put into Standby. Before Standby can be established, the
generator must be stopped by its external switch and the fault must be
cleared.
System Status
BatLev
Load
AC1 1150W 3202V
E--F
1235W
Battery 20.4A 53.9V
Menu
Select Device
FSW3012
EMS
System Settings
XAGS
XAGS 00: Setup
Clear Faults Warnings
View Device Info
[ManualOff]
GenMode
[Operating]
XAGS 00: Setup
Clear Faults Warnings
View Device Info
[ManualOff]
GenMode
Mode
Mode [Standby]
Freedom SW System
Home Screen
Select Device Menu
AGS Settings Menus
From the Freedom
SW System Home
Screen, press
Enter.
Use the arrow
buttons to highlight
“XAGS”.
Press Enter.
Use the arrow
buttons to highlight
“Mode.”
Press Enter.
To put the AGS in Standby Mode:
1
Use the arrow
buttons to change
the setting from
[Operating] to
[Standby].
Press Enter.
2 3