Chapter 1: Operation 5
Setting alarm conditions
The alarm threshold screens are accessed with the disp key (see the
Using the
disp key
flow chart), and enable you to switch alarms on or off and set the alarm
thresholds. The alarm threshold screens are:
Maximum true wind speed alarm.
Low true wind speed alarm.
High apparent wind angle alarm.
Low apparent wind angle alarm.
To set up an alarm, carry out the
Switching alarms on and off
, and
Setting alarm
threshold
procedures, as necessary.
Switching alarms on and off
Use the
disp key to display the required threshold screen, then press the tack key
for approximately one-second, to toggle the alarm either on (i.e. so the alarm
threshold value is displayed) or OFF, as required.
Setting alarm thresholds
To set an alarm threshold:
1. Use the
disp key to display the required threshold screen, then momentarily
press the
vmg and tack keys to enter the threshold adjust mode (indicated
by the displayed value flashing).
2. Use the
vmg (decrement) or tack (increment) key to set the required thresh-
old value. You can set:
The maximum (MAX) and minimum (LO) true wind speed, to any value
between 0 and 99 kts. Conflicting threshold values cannot be set, i.e. you
cannot set the MAX threshold to a lower value than the LO.
High (HI) and low (LO) apparent wind angle, to any value from 0 to
° 180°.
3. Momentarily press the
vmg and tack keys to leave the threshold adjust
mode.
Note:
The alarm threshold screens are not available on repeater instruments so alarm
thresholds can be set up only on master instruments.