A SERVICE OF

logo

HandyTone -286 User Manual Grandstream Networks, Inc.
26
Message Waiting
350 440 10
10
Confirmation
350 440 10
10
Audible Ringing
440 480 200
400
Busy Tone
480 620 50
50
Reorder Tone
480 620 25
25
Receiver
Offhook Tone
1400 2600 10
10
Update
All Rights Reserved Grandstream Networks, Inc. 2005
Admin Password
Administrator password. Only administrator can configure the “Advanced
Settings” page. Password field is purposely left blank for security reason after
clicking update and saved. The maximum password length is 25 characters.
SIP Server
This field contains the URI string or the IP address. e.g. sip.my-voip-
provider.com; 192.168.1.200:5066
Outbound Proxy
This field contains the URI string or the IP of the outbound proxy. If there is no
outbound proxy, this field SHOULD be left blank. If it is not blank, all
outgoing requests will be sent to this outbound proxy.
SIP User ID
This field contains the user part of the SIP address for this phone. e.g., if the
SIP address is: sip:my_user_id@my_provider.com, then the SIP User ID is:
my_user_id. Please do NOT include the preceding “sip:” scheme or the host
portion of the SIP address in this field. It is given by VoIP service provider.
Authenticate ID
SIP service subscriber’s Authenticate ID used for authentication. It can be
identical to or different from SIP User ID and given by VoIP service provider.
Authenticate
Password
SIP service subscriber’s account password. It is given by VoIP service
provider.
Name
SIP service subscriber’s name which will be used for Caller ID display.
Home NPA
Local area code for North American Dial Plan.
Preferred Vocoder
HandyTone-286 supports up to 7 different vocoder types including G711-ulaw
(PCMU), G711-alaw (PCMA), G723, G729A, G726-32, and iLBC. Depending
on the product model, some of these vocoders may not be provided in standard
release.
A user can configure vocoders in a preference order that will be offered in SIP
INVITE message.