EPSON FX-2180 Service Manual Chapter 4 Disassembly and Assembly
4-18
4.2.11.4 Removing the Right Sub Frame Assembly
1.
Remove the printer cover, front and rear edge guide assemblies, front
cover, paper eject assembly, and front and rear tractor units. (See
section 4.2.1.)
2.
Remove the panel board assembly. (See section 4.2.2.)
3.
Remove the upper housing assembly. (See section 4.2.7.)
4.
Remove the printer mechanism. (See section 4.2.11.)
5.
Remove the PF motor assembly. (See section 4.2.11.2.)
6.
Remove the two CBS screws (3
×
6 and 3
×
8) securing the right sub
frame.
7.
Remove the right sub frame from the right frame.
right sub fram e
CBS screw (3 x 6)
CBS screw (3 x 8)
Figure 4-25. Removing the Right Sub Frame
IMPORTANT
The tightening torque for the CBS screws (3 ×× 6
and 3 ×× 8) is 0.78 - 0.98 Nm (8 - 10 Kgf-cm).
Adjust the bidirectional print alignment. (See
Chapter 5.)
4.2.11.5 Removing the Right Frame Assembly
1.
Remove the printer cover, front and rear edge guide assemblies, front
cover, paper eject assembly, and front and rear tractor units. (See
section 4.2.1.)
2.
Remove the panel board assembly. (See section 4.2.2.)
3.
Remove the upper housing assembly. (See section 4.2.7.)
4.
Remove the printer mechanism. (See section 4.2.11.)
5.
Remove the platen assembly. (See section 4.2.8.)
6.
Remove the PG sensor assembly. (See section 4.2.11.3.)
7.
Remove the right sub frame assembly. (See section 4.2.11.4.)
8.
Remove the hexagonal nut (M4) securing the gap adjust lever. Then
remove the lever from the right frame assembly.
9.
Remove the CBS screw (3
×
6) securing the platen cover to the right
frame assembly.
10.
Remove the two CBS screws (3
×
6) securing the right frame
assembly at the positions shown in Figure 4-26.
11.