Chapter 3 Installing the Switch
Installation Guidelines
3-6
User Guide for the Catalyst Express 520 Switches
OL-12761-02
The heat sinks and the bottom of the Catalyst Express 520-8PC-K9 switch
might be hot to the touch if the switch is operating at its maximum
temperature 113°F (45°C) and is in an environment that exceeds normal room
temperature (such as in a closet, in a cabinet, or in a closed or multirack
assembly).
Airflow around the switch and through the vents is unrestricted.
Note We strongly recommend that you allow at least 3 inches (7.6 cm) of
clearance around the ventilation openings to prevent airflow
restriction and overheating.
Do not stack switches or place switches side-by-side unless they are
separated on all sides by at least 3 inches (7.6 cm) of clearance from each
other.
Do not place any items on the top of the switch.
Allow at least 1.75 inches (4 cm) of clearance above each switch in the rack.
Do not wall-mount the switch with its front panel facing up or sideways.
According to safety regulations, wall-mount the switch with its front panel
facing down to prevent airflow restriction and to provide easier access to the
cables.
Clearance to front and rear panels is such that
Airflow around the switch and through the vents is unrestricted.
Front-panel LEDs can be easily read.
Access to ports is sufficient for unrestricted cabling.
AC power cord can reach from the AC power outlet to the connector on
the switch rear panel.
Cabling is away from sources of electrical noise, such as radios, power lines,
and fluorescent lighting fixtures.
Cabling is safely away from other devices that might damage the cables.
For additional cabling guidelines, see the “Cabling Guidelines” section on
page A-10.