user manual
TCS series
tcs manual
page 14
Loudspeaker Connections
TCS series enclosures are provided with a recessed connector panel housing a single
Neutrik Speakon NL4MP connector wired in parallel with a 4-way terminal strip, or in the
case of the TCS-12M and TCS-15M wedge monitors via two Neutrik Speakon NL4MP
connectors wired in parallel. Either can be used for the input, the other being available as
an output for looping to further TCS enclosures. Note that looping out to additional
enclosures has the effect of reducing the total load impedance on the amplifier. For
example, two 8 ohm cabinets in parallel give a combined total impedance of 4 ohms.
Never connect loudspeakers to a power amplifier whose total combined impedance is
lower than the amplifier’s recommended minimum load impedance. Do not use the loop-
out connection to connect any other type of loudspeaker as permanent damage may
result!
The cable end Speakon connector should be wired as follows:
Positive output Pin 1 +
Negative output Pin 1 -
Please take care if XLR’s, binding posts or other dual connector systems are used at the
amplifier end of the loudspeaker cables (jack plugs/sockets should not be used) where
there is a possibility of the cables being reversed. It is highly recommended that Neutrik
Speakons or other heavy duty non-reversible connectors are used.