Sharp MD-MS702 MP3 Player User Manual


 
Recording from the microphone (Mic synchro recording)
The recording will begin automatically in response to a noise or a person speaking. When
the sound stops, the recording will pause. This function is convenient when recording
lectures, conferences, etc.
RECORDING USING A MICROPHONE
VOL /
NAME
Stereo microphone
(commercially available)
To the MIC IN jack
1 Connect the stereo microphone to the
MIC IN jack on the main unit.
When a microphone is connected to
this unit, the unit will automatically
switch to input from the microphone.
2 Insert a recordable Minidisc.
3 Press the REC button.
A monaural, long-play recording
mode is available. (Page 17)
Timed identification marks can be
created while recording. (Page 15)
4 Press the or button to adjust
the recording level.
Adjust the recording level so that the
maximum sound volume from the
source makes the reading swing be-
tween -4 dB and 0 dB.
When the recording level display is
changed from “MIC H” to “MIC L”,
the sound will be interrupted momen-
tarily. This is normal.
5 Press the ENTER/F.PLAY/SYNCHRO
button to select the synchro recording
level. (This level can be changed, even
while recording.)
Refer to the following table.
When the microphone input is set to
MIC SYNC H, recording will start
when a sound is detected at the
lowest volume. If the unit starts
recording too often due to low, un-
wanted noises, set the microphone
input to MIC SYNC L.
0dB
-4dB
Synchro recording
level display
Sound level at which
to start recording
MIC SYNC H
MIC SYNC L
Mic input
-24dB
-12dB
13
MD-MS702