MODEL 110 AUTORANGING DIGITAL MULTIMETER
2
DC Current (uA and mA - Autoranging):
Range Resolution Accuracy
Burden
Voltage
Overload Protection
400uA 0.1uA 1%+2 <0.25V 0.5A / 250V Fast Blow Fuse
4000uA 1uA 1%+2 <1V 0.5A / 250V Fast Blow Fuse
40mA 10uA 1%+2 <0.25V 0.5A / 250V Fast Blow Fuse
400mA 100uA 1%+2 <1.5V 0.5A / 250V Fast Blow Fuse
10A 10mA 1.2%+2 0.35V 10A / 250V Fast Blow Fuse
Resistance (Autoranging):
Range Resolution Accuracy Test Voltage Overload Protection
400 ȍ 0.1 ȍ 0.75%+2 <1.5VDC 600Vrms
4K ȍ 1 ȍ 0.75%+2 <1.5VDC 600Vrms
40K ȍ 10 ȍ 0.75%+2 <1.5VDC 600Vrms
400K ȍ 100 ȍ 0.75%+2 <1.5VDC 600Vrms
4M ȍ 1K ȍ 0.75%+2 <1.5VDC 600Vrms
40M ȍ 10K ȍ 1.2%+3 <1.5VDC 600Vrms
Continuity Beeper:
Range Active Range Test Voltage Overload Protection
Under 40 ȍ <1.5V 600Vrms
Diode Tester:
Range Resolution Accuracy Test Current Test Voltage Overload Protection
1mV 1%+ 2 <1mA <3.2V 600Vrms
Frequency (Autoranging):
Range Resolution Accuracy Sensitivity Overload Protection
4 KHz 1Hz 0.1%+1 <300mVpp 600Vrms
40KHz 10Hz 0.1%+1 <300mVpp 600Vrms
400KHz 100Hz 0.1%+1 <300mVpp 600Vrms
4MHz 1KHz 0.1%+1 <3Vpp 600Vrms
40MHz 10KHz 0.1%+1 <3Vpp 600Vrms