La Crosse Technology WS-1515U-IT Portable Radio User Manual


 
80
Air pressure
histogram
LCD SCREEN
The LCD screen is split into 5 sections displaying the following information:
1. Time and date/ indoor temp/ second
2. Wind data
3. Outdoor temperature, Dew point and humidity,
4. Air pressure, Rainfall data, Air pressure history and Weather forecast
icon.
* When the signal from the transmitter/ or Rain sensor is successfully
received by the Weather Station, this icon will be switched on. (If not
successful, the icon will not be shown on the LCD). User can therefore
easily see whether the last reception was successful (“ON” icon) or not
(“OFF” icon). On the other hand, the short blinking of the icon shows that a
reception is being done at that time.
Outdoor temperature
or dew point
in °F or ºC
Wind direction display
and wind speed in
Beaufort scale
Calendar display
Weather tendency
indicator
Time display
Time alarm icon
Outdoor relative
humidity in %
Weather forecast
icon
Relative air pressure
display in inHg or hPa,
or total and 24h rainfall
display in inch or mm
Wind speed or gust
in mph, km/h or m/s
Wind Chill in
F or C
Wind speed Hi
alarm icon
Outdoor Humidity
alarm icon
Outdoor temp.
alarm icon
Low battery
Indicator (rain sensor)
Low battery Indicator (Thermo-hygro)
Buzzer off indicator
Transmitter signal
reception icon
Low battery Indicator (weather center)
81
*In normal display user may press the SET key shortly to toggle between
Mode 1 and Mode 2 display:
Mode 1 : Wind speed, outdoor temperature and relative pressure reading
are shown.
Mode 2 : Wind Gust, Dew Point temperature and Rainfall reading are
shown.
MANUAL SETTING:
The following manual settings can be changed once the SET key is
pressed and hold for about 3 seconds:
LCD contrast setting
Manual time setting
12/24 hour time display
Calendar setting
°F/ °C temperature unit setting
Wind speed unit
Rainfall unit setting
Air pressure unit setting
Relative pressure reference value setting
Weather tendency threshold value
Storm warning threshold value
Alarm On/ Off setting
LCD CONTRAST SETTING
The LCD contrast can be set within 8 levels, from "LCD 1" to "LCD 8"
(default setting is LCD 5):
1. Press the SET key, the contrast level digit will start flashing.
2. Use the + or MIN/MAX key to adjust the level of contrast.
3. Confirm with the SET key and enter the MANUAL TIME SETTING.
Wind speed icon
Outdoor temp
icon
Rel Pressure
icon
Wind gust icon
Dew point icon
Rainfall icon
In Mode 1, this reception
icon is showing the
condition of the
reception of the signal
from Thermo-hygro
transmitter
In Mode 2, this
reception icon is
showing the condition
of the reception of the
signal from Rain
sensor
Flashing
82
"Date. Month." (for 24h time display)
"Month. Date." (for 12h time display)
Année
MANUAL TIME SETTING:
You then may manually set the time of the clock by following the steps
below:
1. The hour digit will start flashing.
2. Use the + or MIN/MAX key to set the hour.
3. Press the SET key to switch to the minutes. The minute digit will start
flashing.
4. Use the + or MIN/MAX key to set the minute.
5. Confirm the time with the SET key and enter the 12/24 HOUR TIME
DISPLAY SETTING.
12/24 HOUR TIME DISPLAY SETTING:
The time can be set to view as 12-hour or 24-hour format. The default time
display mode is 12-h. To set to 24-h time display:
1. Use the + or MIN/MAX key to toggle the value.
2. Confirm with the SET key and enter the CALENDAR SETTING.
CALENDAR SETTING:
The date default of the Weather Center is 1. 1. of year 2005. The date can
be set manually by proceeding as follows.
1. The year digit starts flashing.
2. Use the + or MIN/MAX key to set the year. The range runs from "00"
(2000) to "99" (2099).
3. Press the SET key to confirm the year and enter the month setting.
The month digit will start flashing.
4. Use the + or MIN/MAX key to set the month.
5. Press the SET key to confirm the month and enter the date setting
mode. The date digit will start flashing.
6. Use the + or MIN/MAX key to set the date.
7. Confirm all calendar settings with the SET key and enter the °F/°C
TEMPERATURE UNIT SETTING.
°F/°C TEMPERATURE UNIT SETTING
The temperature display can be selected to show temperature data in °F or
°C. (default °F)
1. The temperature unit is flashing
2. Use the + or MIN/MAX key to toggle between “°F” or “°C”.
3. Confirm with the SET key and enter the WIND SPEED UNIT
SETTING.
Minutes flashing
Hour
flashing
Digit flashing
Flashing
83
WIND SPEED UNIT SETTING
The wind speed unit can be set as mph (mile per hour), km/h (kilometer per
hour), or m/s (meter per second). The default unit is mph.
1. Use the + or MIN/MAX key to toggle between the unit “mph”, “km/h”
or “m/s”
2. Confirm with the SET key and enter the RAINFALL UNIT SETTING.
RAINFALL UNIT SETTING
The rainfall unit can be set as inch or mm. The default unit is inch.
1. Use the + or MIN/MAX key to toggle between the unit “inch” or “mm”
2. Confirm the unit with the SET key and enter the RELATIVE AIR
PRESSURE UNIT SETTING
RELATIVE AIR PRESSURE UNIT SETTING
The relative air pressure can be set as inHg or hPa. The default unit is inHg.
1. Use the + or MIN/MAX key to toggle between the unit “inHg" or “hPa”
2. Confirm the unit with the SET key and enter the RELATIVE
PRESSURE REFERENCE VALUE SETTING.
RELATIVE PRESSURE REFERENCE VALUE SETTING
Note:
The default reference pressure value of the barometer is 29.91inHg when
batteries are first inserted. For an exact measurement, it is necessary to
first adjust the barometer to your local relative air pressure (related to
elevation above sea level). Ask for the current atmospheric pressure of
your home area (Local weather service, www, optician, calibrated
instruments in public buildings, airport).
The relative air pressure can be manually set to another value within the
range of 27.17 to 31.90 inHg (919 to 1080 hPa) for a better reference.
1.The current relative pressure value will start flashing
2.Use the + or MIN/MAX key to increase or decrease the value. Continually
holding the key will allow the value to increase faster.
3.Confirm with the SET key and enter the WEATHER TENDENCY
SENSITIVITY VALUE SETTING.
Note:
This feature is useful for those who live at elevations above sea level, but
want their air pressure display to be based on sea level elevation.
Flashing
Flashing
Flashing
Flashing
MPH