Infinity F849 Portable Speaker User Manual


 
4-3
Symptom Action Notes
Infinity does not start 1. Check cable connections at timer,
electronic timer but start cable harness (or deck plate) and Infinity.
horn sounds properly.
2. Make sure you are using a Colorado
Time Systems timer (Normally Open
circuit)
3. Possible electronic timer failure —
attempt to start timer manually.
No start or recall tones at 1. Make sure the starter is holding down See instructions on page 3-1.
speaker(s). the push-to-talk thumb switch when
pressing the start button on the
microphone.
2. Check wired microphone connector See Figure B for location of this item.
on the Infinity connector panel.
3. Check speaker connector at external
speaker and on Infinity connector panel.
4. The microphone switch may be bad—
substitute another microphone.
No public address output at 1. Check volume control level on the See Figure B for location of this item.
speaker(s). Infinity connector panel.
2. Check speaker connector at external
speaker and on Infinity connector panel.
3. Check microphone connection on the See Figure B for location of this item.
Infinity connector panel.
Strobe does not flash 1. Allow a few seconds between starts
for strobe to recharge.
2. Return Infinity to CTS for repair
Experiencing Feedback 1. Move further away from the base unit
or behind the speakers in use.
2. Turn down the speaker volume