IBM 3590 Portable Media Storage User Manual


 
Table 34. FID Messages (continued)
FID Description Customer Action
BD-C0 Drive Problem Call for service
C1
Drive or Power
Problem
This error may be caused by reduction of power or a
power failure to the drive. If not a power failure, call
for service.
C2-C4 Drive Problem Call for service
C5
Cartridge or Drive
Problem
1. Isolate between media and hardware. See
Appendix A. Media/Hardware Problem Isolation
on page 99.
2. Call for service if problem remains.
C6 Drive Problem Call for service
C7
Cartridge or Drive
Problem
1. Isolate between media and hardware. See
Appendix A. Media/Hardware Problem Isolation
on page 99.
2. Call for service if problem remains.
C8-D2 Drive Problem Call for service
D3
Cartridge or Drive
Problem
1. Isolate between media and hardware. See
Appendix A. Media/Hardware Problem Isolation
on page 99.
2. Call for service if problem remains.
D8-E4 Drive Problem Call for service
E5
Drive Microcode
Problem
Call for service
E6-EF Drive Problem Call for service
F0-F2
Cartridge or Drive
Problem
1. Isolate between media and hardware. See
Appendix A. Media/Hardware Problem Isolation
on page 99.
2. Call for service if problem remains.
F3
Cartridge or Drive
Problem
1. Isolate between media and hardware. See
Appendix A. Media/Hardware Problem Isolation
on page 99.
2. Call for service if problem remains.
F4 Drive Problem Call for service
F5
SCSI Bus or Fibre
Channel Problem
See SCSI Buson page 105 or Fibre Channelon
page 109.
F6
Cleaning needed
for performance
reasons.
Clean the tape drive (run clean tape). If this FID
continues to be posted, call for service.
FE
Cartridge or Drive
Problem
1. Isolate between media and hardware. See
Appendix A. Media/Hardware Problem Isolation
on page 99.
2. Call for service if problem remains.
Appendix B. FID Messages
103