Dell FE300 Portable Media Storage User Manual


 
1-6 Platform Guide
www.dell.com | support.dell.com
6400 PCI bus 0: PCI slot 1 is 32-bit,
33-MHz
PCI bus 1: PCI slots 2 through 5
are 64-bit, 33-MHz
PCI bus 2: PCI slots 6 and 7 are
64-bit, 33/66-MHz
For dual HBA
configurations, Dell
recommends installing
the HBAs on separate
PCI buses (PCI buses 1
and 2) to balance the
load on the system.
Install the new or
existing DRAC II in
PCI slot 1.
N/A
6450 PCI bus 0: PCI slot 1 is 32-bit,
33-MHz
PCI bus 1: PCI slots 2 through 5
are 64-bit, 33-MHz
PCI bus 2: PCI slots 6 and 7 are
64-bit, 33/66-MHz
For dual HBA
configurations, Dell
recommends installing
the HBAs on separate
PCI buses (PCI buses 1
and 2) to balance the
load on the system.
Install the new or
existing DRAC II in
PCI slot 1.
N/A
6600 PCI bus 0: PCI slot 1 is 32-bit,
33 MHz
PCI/PCI-X bus 1: PCI slot 2 and
3 are 64-bit, 33–100 MHz
PCI/PCI-X bus 2: PCI slot 4 and
5 are 64-bit, 33–100 MHz
PCI/PCI-X bus 3: PCI slot 6 and
7 are 64-bit, 33–100 MHz
PCI/PCI-X bus 4: PCI slot 8 and
9 are 64-bit, 33–100 MHz
PCI/PCI-X bus 5: PCI slot 10
and 11 are 64-bit, 33–100 MHz
For dual HBA
configurations, Dell
recommends installing
the HBAs on separate
PCI buses to balance the
load on the system.
Install the new or
existing DRAC III in
slot 1.
Install the RAID
controller in PCI
slot 2 or 3.
Table 1-3. PCI Slot Assignments for PowerEdge Cluster Nodes (continued)
PowerEdge
System
PCI Buses HBA DRAC II or III RAID Controller