• If the indication "noCArd" appears, the data card is not
recognized. Check whether the card has been inserted properly.
• If the indication "Cd Err" appears, there is a problem with the
data card. Format the card again.
With each push of the [INTERNAL/DATA CARD] key, the selection
cycles through the following three settings.
• int
ST-224 bulk data stored internally in the backup memory. Pad data
comprised in the bulk data can be loaded into main memory and
assigned as samples to pads.
• CardXX (XX = 1 - 99)
ST-224 bulk data stored on a data card. Pad data comprised in the
bulk data can be loaded into main memory and assigned as
samples to pads.
• FileXX (XX = 1 - 99)
Stereo or mono WAV files stored on a data card. Waveform data
comprised in files can be loaded into main memory and assigned
as samples to pads.
• AIFFXX (XX = 1 - 99)
Stereo or mono AIFF files stored on a data card. Waveform data
comprised in files can be loaded into main memory and assigned
as samples to pads.
• When storing WAV files or AIFF files on a data card for use with
the ST-224, the files should be named "??.WAV" or "??.AIF" (??
stands for a number from 01 - 99). Files with other names are
disregarded.
The ST-224 can individually extract pad data (waveform data and parameter setting information for a
specific pad) from bulk data stored on a data card.
It is also possible to load regular waveform files (WAV or AIFF files) stored on a data card. This lets you
use WAV files or AIFF files created on a computer as samples in the ST-224.