3. Remove the lead wires from the heating element and check the element resistance using a VOM.
A. If resistance readings are not correct, replace heating element.
1) To replace an element, drain water from boiler shell.
2) Remove cover of contactor box, remove electric wires to that element's terminals, remove bolts
through flange of element and pull element forward.
NOTE:
When replacing an element, always use a new gasket and ensure that the flange and tube surfaces which
contact the gasket are clean. If removed element shows a pronounced scale build-up on its heating tubes, the
other elements should be removed and mechanically cleaned to remove the scale. This will prolong their life. DO
NOT immerse elements in a chemical solution to descale.
4. After new element is installed, check unit for proper operation.
VOLTAGE
TOTAL
KW
NUMBER
OF
ELEMENTS
KW
PER
ELEMENT
AMPERAGE
PER LINE
RESISTANCE
PER
ELEMENT
(OHMS)
1 PH 3 PH
208 18 2 9 87 50 14.42
240 18 2 9 75 44 19.20
480 18 2 9 22 76.80
*220/380
240/415
18 2 9 25 19.20
208 24 4 6 116 68 21.63
240 24 4 6 100 58 28.80
480 24 4 6 29 115.20
*220/380
240/415
24
4 6 57.8 28.80
208 24 2 12 116 68 10.82
240 24 2 12 100 58 14.40
480 24 2 12 29 57.60
*220/380
240/415
24 2 12 34 14.40
208 36 4 9 100 14.42
240 36 4 9 87 19.20
480 36 4 9 44 76.80
*220/380
240/415
36 4 9 50 19.20
208 42 4 10.5 117 12.36
240 48 4 12 116 14.40
480 48 4 12 58 57.60
*220/380
240/415
48 4 12 67 14.40
NOTES:
1. Values in the table are nominal. Tolerance is +/-10 %.
2. Asterisk (*) indicates 3 phase/4wire.
3. Each heater has three internal elements.