1 − Introduction
8 TASCAM SS-R1
The pinouts of the CONTROL I/O (PARALLEL) terminal
on the rear panel (see “Rear panel” on page 10) are:
Pin Function IN/OUT
1 GND —
2 Play/Flash 1 In
3 Stop/Flash 2 In
4 Record/Flash 3 In
5
≤
(Next)/Flash 4
In
6
µ
(Previous)/Flash 5
In
7 Flash Load In
8 Fader Start In
9 Flash Tally Out
10 Ready Tally Out
11 Record Tally Out
12 Stop Tally Out
13 Play Tally Out
14 Remote Select*
2
In
15 Ready/Flash 6 In
16 Call/Flash 7 In
17 Auto Cue/Flash 8 In
18 Auto Ready/Flash 9 In
19 Pitch/Flash 10 In
20 Flash Page*
3
In
21 EOM Tally Out
22 CF Tally Out
23 — —
24 — —
25 +5V*
1
—
In: External command reception active flow
(operates at 30 ms or longer of ground)
Out: transport status by open collector
Indication signal (maximum voltage 15 V, maximum current
50 mA)
*1 Maximum supplied current is 50 mA.
*2 Pin 14 (Remote Select)
When this pin is high, the input pins for which the above
table lists two commands separated by a “/” (pins 2–6
and 15–19) will perform the first-listed function, and can
be used as conventional parallel controllers.
When this pin is low, the above-listed input pins will
function as flash start keys.
*3 Pin 20 (Flash Page)
When pin 14 (Remote Select) is low, the assigned tracks
will be as follows according to the high/low state of pin
20.
#14 #20 Flash-start status
Low High 1–10
Low Low 11–20
Tall signals are open collector, with a maximum current
of 50 mA. Input signals are active when low (ground)
for ≥ 30 ms.
A fader start/stop control should be wired according to the
following schematic:
START
STOP
Pin 1
FADER START
Pin 8
GND
PARALLEL
Control connections