A SERVICE OF

logo

46D0232
20
SS38 Direct Vent Gas Stove
FP1977
external regulator

Use proper gas type for the stove you are installing. If you have conflicting gas type, do not install
stove. See dealer where you purchased the stove for proper stove for your gas type or conversion
kit.

External
Regulator
100 lb. (min)
Propane/LP
Supply Tank
Vent Pointing
Down






     
     

     
   


Before installing stove and burner system, make sure you have the items listed below.
External regulator Piping (check local codes) Sealant (resistant to propane/LP gas)
(supplied by installer) Test gauge connection* • Sediment trap (recommended)
Equipment shutoff valve* Tee joint Pipe wrench
approved flexible gas line with gas connector (if allowed by local codes — not provided)
* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge
connection. Purchase the CSA design-certified equipment shutoff valve from your dealer.
For propane/LP connections only, the installer must supply an external regulator. The external regulator will reduce
incoming gas pressure. You must reduce incoming gas pressure to between 11 and 13 inches of water. If you do not
reduce incoming gas pressure, burner system regulator damage could occur. Install external regulator with the vent
pointing down as shown in Figure 27. Pointing the vent down protects it from freezing rain or sleet.
FP1977
Figure 27 -
External Regulator with Vent Pointing Down
(Propane/LP Only)

       
 




     



When using copper of flex connectors use only fittings
approved for gas connections. The gas control inlet is
3/8" NPT.