A SERVICE OF

logo

9 b. Set up for recirculation
mode connection
If the hood can not be installed for air
extraction the appliance must be con-
nected for recirculation.
The following parts, available through
your Miele Dealer or from the Miele
Technical Service Department are
necessary for using the appliance in re-
circulation mode:
Recirculation conversion kit 5
(125 mm) diameter includes an ex-
haust grill, hose, hose clip
Active Charcoal Filter (see Techni-
cal data)
Connection
When installing the venting hood in a
cabinet the exhaust grill
c
has to be
fitted in the top of the unit. The vent
connection (vent socket)
b
and the ex-
haust grill
c
are joined together with a
pipe or flexible duct cut to size
d
.
If the front of the unit is ceiling height
then an appropriate cut-out must be
made in the front panel
e
.
When installing the ventilation grill
make sure that the slats in the grill point
towards the center of the room and not
towards a wall or the ceiling.
The slot for the Active Charcoal Filter is
located on the front of the appliance.
Install the Active Charcoal Filter (see
Cleaning and care).
10. Electrical connection
Refer to the notes in Electrical con-
nection and Warning and Safety
instructions before connecting to
the electrical supply.
EXT model venting hoods are de-
signed for use with an external fan,
i.e. the fan is to be installed in a wall
outside the room.
Electrical connection is made by a
power cord with plug. Separate installa-
tion instructions are supplied with the
external fan.
Installation