Insulation Resistance Measurement Specifications
Test Voltages 500V 1000V 2500V 5000V *
Measurement
Range
(Auto-ranging)
0.005~6.000M 0.005~6.000M 0.05~60.00M 0.05~60.00M
6.01~60.00M 6.01~60.00M 60.1~600.0M 60.1~600.0M
60.1~600.0M 60.1~600.0M 0.61~6.00G 0.61~6.00G
0.61~6.00G 0.61~6.00G 6.1~60.0G 6.1~60.0G
Open circuit
Voltage
DC 500V
+20%,-0%
DC 1000V
+20%,-0%
DC 2500V
+20%,-0%
DC 5000V
+20%,-0%
Rated
current
1~1.2mA
(0.5 M load)
1~1.2mA
(1 M load)
1~1.2mA
(2.5 M load)
1~1.2mA
(5 M load)
Short-circuit
current
Approx.1mA
Accuracy
0.005~600.0M +2.5% reading +15 digits
0.61~6.00G +3% reading +15 digits
6.1~60.0G +4% reading +15 digits
5~6000VDC +1.5%reading +5 digits
Note on voltage
display in IR test
mode
In Insulation Resistance test mode, this device is used to check whether or not the
electric charge stored in the equipment under test has been discharged. During an
Insulation Resistance test, the voltage value displayed on the LCD above the
resistance measurement is the test reference voltage value.
* NOTE: For 5000V IR measurements, use of the ac adapter to power the unit is recommended.
AC/DC Voltage Specifications
Range Resolution Accuracy
0.5 to 600 VAC (40 to 400Hz)
0.1V
±1% of rdg + 5d (40 to 60 Hz)
±2.5% of rdg + 10d (61 to 400 Hz)
0.5 to 600 VDC ±1% of reading + 5 digits
Low Resistance Measurement and Continuity Specifications
Range Resolution Accuracy
0.1 to 600 0.1
±1.5% rdg + 10d
601 to 6.00k 0.001k
±1.5% rdg + 15d
Continuity Buzzer
Triggers if the resistance is 50or lower
Open Circuit Voltage 4.5V minimum
Short Circuit Current 200mA minimum
Copyright©2014FLIRSystems,Inc.