![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/c8/6c80647d-e6d2-4086-b119-2ce8a0f221e8/6c80647d-e6d2-4086-b119-2ce8a0f221e8-bg24.png)
EPSON AcuLaser C1100 Revision B
PRODUCT DESCRIPTION Electrical Characteristics 36
1.7 Electrical Characteristics
NOTE: The following sections do not include any optional units.
1.7.1 Electrical Fast Transient /Bursts (AC Line Noise)
Ensure the following conditions using evaluation methods compliant with IEC61000-
4-4.
1 kV : No errors excluding insignificant dot errors
2 kV : No damage to parts
1.7.2 Instantaneous Outages
No effect on printing quality.
DIP : 1 cycle 100% (at -10% of rated current)
1.7.3 Resistance to Static Electricity
Ensure the following conditions using evaluation methods compliant with
IEC61000-4-2 CISPR 24.
Contact electric discharge 5 kV
: No error on any device after applying
Aerial electric discharge 10 kV
: No error on any device after applying
1.7.4 Inrush Current
1/2 cycle
100 A or less (0-peak) : Including heater inrush
(Conditions: Above 23 ºC with cold start)
1.7.5 Insulation Resistance
10 MΩ or more
1.7.6 Withstand Voltage
There should be no break down during application of the voltages shown below.
Leak current should be 20mA or less when applying the voltage for one minute.
1.7.7 Leak Current
120 V : 3.5mA or less
220 V series : 3.5mA or less
Table 1-24. Withstand Voltage
Between inlet and non-charged
metal parts
Between primary and secondary
power transformers.
120V AC 1000 V AC 1500 V
200V series AC 2000V AC 3000V