![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/c8/6c80647d-e6d2-4086-b119-2ce8a0f221e8/6c80647d-e6d2-4086-b119-2ce8a0f221e8-bg158.png)
EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY TRANSFER 344
4.5.2 SENSOR FUSER IN
REMOVAL
1. Remove CHUTE ASSY-FSR. (p.341)
2. Remove the 2 screws (silver, with washer, tapping, 8 mm) fastening DIODE
FUSER to CHUTE ASSY-FSR.
3. Remove DIODE FUSER from CHUTE ASSY-FSR.
4. Remove the screw (silver, with washer, tapping, 8 mm) fastening CHUTE-FSR
and PLATE DIS 2ND to CHUTE ASSY-FSR.
5. Remove PLATE DIS 2ND from CHUTE ASSY-FSR.
6. Remove CHUTE-FSR from CHUTE ASSY-FSR.
7. Disconnect connector (P/J111) from SENSOR FUSER IN.
8. Remove the screw (silver, tapping, 6 mm) fastening SENSOR FUSER IN to
CHUTE ASSY-FSR.
9. Remove SENSOR FUSER IN from CHUTE ASSY-FSR.
Figure 4-59. Removal of SENSOR FUSER IN (1)
Leg_Sec03_144FB
CAUTION
2)
2)3)
4)
5)
6)