1.3.10 Electric Specifications
120 V version
Rated voltage AC 120 V
Input voltage range AC 103.5 to 132 V
Rated frequency renege 50 to 60 Hz
Input frequency range 49.5 to 60.5 Hz
Rated current 0.7 A (maximum)
Power consumption Approximately 21 W (ISO/IEC 10561 Letter pattern)
Energy Star program compliant
Insulation resistance 10 M ohms min. (Between AC line and chassis, 500 VDC)
Dielectric strength AC 1,000 V rms. For 1 minute or
AC 1,200 V rms. For 1 second (Between AC line and chassis)
220 - 240V version
Rated voltage AC 220 to 240 V
Input voltage range AC 198 to 264 V
Rated frequency renege 50 to 60 Hz
Input frequency range 49.5 to 60.5 Hz
Rated current 0.4 A (maximum)
Power consumption Approximately 21 W (ISO/IEC 10561 Letter pattern)
Energy Star program compliant
Insulation resistance 10 M ohms min. (Between AC line and chassis, DC 500 V)
Dielectric strength AC 1,500 Vrms. For 1 minute (Between AC line and chassis)
1.3.11 Environmental Conditions
Temperature
Operating*
1
10°C to 35°C
Non operating*
2
-20°C to 60°C
1 month at 40 °C (104 °F)
120 hours at 60 °C (140 °F)
Humidity
Operating*
1
20% to 80% RH (without condensation)
Non operating*
2
5% to 85% RH (without condensation)
Resistance to vibration
Operating 0.15 G
Non-operating*
2
0.50 G
Resistance to shock
Operating 1 G within 1 ms
Non-operating*
2
2 G within 2 ms
*1 :Refer to the table below for guaranteed range.
*2 :In shipment container.
Humidity (%)
90
80
70
60
50
40
30
20
10
20
27
30
35
40
Temperature ( C)
.
Operating Environment
Figure 1-7. Environmental Conditions